ETCDIR=/etc LIBDIR=/lib EXTDIR=${DESTDIR}${ETCDIR} MODE=754 DIRMODE=755 CONFMODE=644 all: install create-dirs: install -d -m ${DIRMODE} ${EXTDIR}/rc.d/rc0.d install -d -m ${DIRMODE} ${EXTDIR}/rc.d/rc1.d install -d -m ${DIRMODE} ${EXTDIR}/rc.d/rc2.d install -d -m ${DIRMODE} ${EXTDIR}/rc.d/rc3.d install -d -m ${DIRMODE} ${EXTDIR}/rc.d/rc4.d install -d -m ${DIRMODE} ${EXTDIR}/rc.d/rc5.d install -d -m ${DIRMODE} ${EXTDIR}/rc.d/rc6.d install -d -m ${DIRMODE} ${EXTDIR}/rc.d/rcsysinit.d install -d -m ${DIRMODE} ${EXTDIR}/rc.d/init.d install -d -m ${DIRMODE} ${EXTDIR}/sysconfig create-service-dir: install -d -m ${DIRMODE} ${EXTDIR}/sysconfig/network-devices/services udev_device_dirs: install -d -m ${DIRMODE} ${DESTDIR}${LIBDIR}/udev/devices install -d -m ${DIRMODE} ${DESTDIR}${LIBDIR}/udev/devices/pts install -d -m ${DIRMODE} ${DESTDIR}${LIBDIR}/udev/devices/shm install -d -m ${DIRMODE} ${DESTDIR}${LIBDIR}/udev/devices/net udev_device_links: udev_device_dirs ln -snf /proc/self/fd ${DESTDIR}${LIBDIR}/udev/devices/fd ln -snf /proc/self/fd/0 ${DESTDIR}${LIBDIR}/udev/devices/stdin ln -snf /proc/self/fd/1 ${DESTDIR}${LIBDIR}/udev/devices/stdout ln -snf /proc/self/fd/2 ${DESTDIR}${LIBDIR}/udev/devices/stderr ln -snf /proc/kcore ${DESTDIR}${LIBDIR}/udev/devices/core mknod_devices: udev_device_dirs @if [ "$$UID" = "0" ]; then \ if ! [ -e ${DESTDIR}${LIBDIR}/udev/devices/null ]; then \ mknod -m 0666 ${DESTDIR}${LIBDIR}/udev/devices/null c 1 3 ;\ fi \ fi @if [ "$$UID" = "0" ]; then \ if ! [ -e ${DESTDIR}${LIBDIR}/udev/devices/console ]; then \ mknod -m 0600 ${DESTDIR}${LIBDIR}/udev/devices/console c 5 1 ;\ fi \ fi @if [ "$$UID" != "0" ]; then \ if ! [ -e ${DESTDIR}${LIBDIR}/udev/devices/null ]; then \ echo "You will need to issue the following command as the root user" ;\ echo "" ;\ echo "mknod -m 0666 ${DESTDIR}${LIBDIR}/udev/devices/null c 1 3" ;\ fi \ fi @if [ "$$UID" != "0" ]; then \ if ! [ -e ${DESTDIR}${LIBDIR}/udev/devices/console ]; then \ echo "mknod -m 0600 ${DESTDIR}${LIBDIR}/udev/devices/console c 5 1" ;\ echo "" ;\ fi \ fi install: create-dirs create-service-dir udev_device_dirs udev_device_links install -m ${MODE} clfs/init.d/checkfs ${EXTDIR}/rc.d/init.d/ install -m ${MODE} clfs/init.d/cleanfs ${EXTDIR}/rc.d/init.d/ install -m ${CONFMODE} clfs/init.d/functions ${EXTDIR}/rc.d/init.d/ install -m ${MODE} clfs/init.d/halt ${EXTDIR}/rc.d/init.d/ install -m ${MODE} clfs/init.d/console ${EXTDIR}/rc.d/init.d/ install -m ${MODE} clfs/init.d/localnet ${EXTDIR}/rc.d/init.d/ install -m ${MODE} clfs/init.d/modules ${EXTDIR}/rc.d/init.d/ install -m ${MODE} clfs/init.d/mountfs ${EXTDIR}/rc.d/init.d/ install -m ${MODE} clfs/init.d/mountkernfs ${EXTDIR}/rc.d/init.d/ install -m ${MODE} clfs/init.d/network ${EXTDIR}/rc.d/init.d/ install -m ${MODE} clfs/init.d/rc ${EXTDIR}/rc.d/init.d/ install -m ${MODE} clfs/init.d/reboot ${EXTDIR}/rc.d/init.d/ install -m ${MODE} clfs/init.d/sendsignals ${EXTDIR}/rc.d/init.d/ install -m ${MODE} clfs/init.d/setclock ${EXTDIR}/rc.d/init.d/ install -m ${MODE} clfs/init.d/sysklogd ${EXTDIR}/rc.d/init.d/ install -m ${MODE} clfs/init.d/swap ${EXTDIR}/rc.d/init.d/ install -m ${MODE} clfs/init.d/sysctl ${EXTDIR}/rc.d/init.d/ install -m ${MODE} clfs/init.d/template ${EXTDIR}/rc.d/init.d/ install -m ${MODE} clfs/init.d/udev ${EXTDIR}/rc.d/init.d/ ln -sf ../init.d/network ${EXTDIR}/rc.d/rc0.d/K80network ln -sf ../init.d/sysklogd ${EXTDIR}/rc.d/rc0.d/K90sysklogd ln -sf ../init.d/sendsignals ${EXTDIR}/rc.d/rc0.d/S60sendsignals ln -sf ../init.d/mountfs ${EXTDIR}/rc.d/rc0.d/S70mountfs ln -sf ../init.d/swap ${EXTDIR}/rc.d/rc0.d/S80swap ln -sf ../init.d/localnet ${EXTDIR}/rc.d/rc0.d/S90localnet ln -sf ../init.d/halt ${EXTDIR}/rc.d/rc0.d/S99halt ln -sf ../init.d/network ${EXTDIR}/rc.d/rc1.d/K80network ln -sf ../init.d/sysklogd ${EXTDIR}/rc.d/rc1.d/S10sysklogd ln -sf ../init.d/network ${EXTDIR}/rc.d/rc2.d/S20network ln -sf ../init.d/sysklogd ${EXTDIR}/rc.d/rc2.d/S10sysklogd ln -sf ../init.d/sysklogd ${EXTDIR}/rc.d/rc3.d/S10sysklogd ln -sf ../init.d/network ${EXTDIR}/rc.d/rc3.d/S20network ln -sf ../init.d/sysklogd ${EXTDIR}/rc.d/rc4.d/S10sysklogd ln -sf ../init.d/network ${EXTDIR}/rc.d/rc4.d/S20network ln -sf ../init.d/sysklogd ${EXTDIR}/rc.d/rc5.d/S10sysklogd ln -sf ../init.d/network ${EXTDIR}/rc.d/rc5.d/S20network ln -sf ../init.d/network ${EXTDIR}/rc.d/rc6.d/K80network ln -sf ../init.d/sysklogd ${EXTDIR}/rc.d/rc6.d/K90sysklogd ln -sf ../init.d/sendsignals ${EXTDIR}/rc.d/rc6.d/S60sendsignals ln -sf ../init.d/mountfs ${EXTDIR}/rc.d/rc6.d/S70mountfs ln -sf ../init.d/swap ${EXTDIR}/rc.d/rc6.d/S80swap ln -sf ../init.d/localnet ${EXTDIR}/rc.d/rc6.d/S90localnet ln -sf ../init.d/reboot ${EXTDIR}/rc.d/rc6.d/S99reboot ln -sf ../init.d/mountkernfs ${EXTDIR}/rc.d/rcsysinit.d/S00mountkernfs ln -sf ../init.d/modules ${EXTDIR}/rc.d/rcsysinit.d/S05modules ln -sf ../init.d/udev ${EXTDIR}/rc.d/rcsysinit.d/S10udev ln -sf ../init.d/checkfs ${EXTDIR}/rc.d/rcsysinit.d/S20checkfs ln -sf ../init.d/mountfs ${EXTDIR}/rc.d/rcsysinit.d/S30mountfs ln -sf ../init.d/swap ${EXTDIR}/rc.d/rcsysinit.d/S40swap ln -sf ../init.d/cleanfs ${EXTDIR}/rc.d/rcsysinit.d/S50cleanfs ln -sf ../init.d/setclock ${EXTDIR}/rc.d/rcsysinit.d/S60setclock ln -sf ../init.d/console ${EXTDIR}/rc.d/rcsysinit.d/S70console ln -sf ../init.d/localnet ${EXTDIR}/rc.d/rcsysinit.d/S80localnet ln -sf ../init.d/sysctl ${EXTDIR}/rc.d/rcsysinit.d/S90sysctl if [ ! -f ${EXTDIR}/sysconfig/bootscripts ]; then install -m ${CONFMODE} clfs/sysconfig/bootscripts ${EXTDIR}/sysconfig/bootscripts; fi if [ ! -f ${EXTDIR}/sysconfig/console ]; then install -m ${CONFMODE} clfs/sysconfig/console ${EXTDIR}/sysconfig/; fi if [ ! -f ${EXTDIR}/sysconfig/createfiles ]; then install -m ${CONFMODE} clfs/sysconfig/createfiles ${EXTDIR}/sysconfig/; fi if [ ! -f ${EXTDIR}/sysconfig/modules ]; then install -m ${CONFMODE} clfs/sysconfig/modules ${EXTDIR}/sysconfig/; fi if [ ! -f ${EXTDIR}/sysconfig/rc ]; then install -m ${CONFMODE} clfs/sysconfig/rc ${EXTDIR}/sysconfig/; fi install -m ${MODE} clfs/sysconfig/network-devices/ifup ${EXTDIR}/sysconfig/network-devices/ install -m ${MODE} clfs/sysconfig/network-devices/ifdown ${EXTDIR}/sysconfig/network-devices/ install -m ${MODE} clfs/sysconfig/network-devices/services/ipv4-static ${EXTDIR}/sysconfig/network-devices/services/ install -m ${MODE} clfs/sysconfig/network-devices/services/ipv4-static-route ${EXTDIR}/sysconfig/network-devices/services/ @$(MAKE) mknod_devices install-consolelog: create-dirs install -m ${MODE} contrib/init.d/consolelog ${EXTDIR}/rc.d/init.d ln -sf ../init.d/consolelog ${EXTDIR}/rc.d/rcsysinit.d/S00consolelog install --backup=numbered -m ${CONFMODE} contrib/sysconfig/consolelog ${EXTDIR}/sysconfig/ install-service-mtu: create-service-dir install -m ${MODE} contrib/sysconfig/network-devices/services/mtu ${EXTDIR}/sysconfig/network-devices/services minimal: create-dirs create-service-dir udev_device_dirs udev_device_links sed -e 's|/bin:/usr/bin:/sbin:/usr/sbin|/tools/bin:/tools/sbin:/bin:/sbin|g' clfs/init.d/functions > clfs/init.d/functions.minimal install -m ${MODE} clfs/init.d/checkfs ${EXTDIR}/rc.d/init.d/ install -m ${MODE} clfs/init.d/cleanfs ${EXTDIR}/rc.d/init.d/ install -m ${CONFMODE} clfs/init.d/functions.minimal ${EXTDIR}/rc.d/init.d/functions install -m ${MODE} clfs/init.d/halt ${EXTDIR}/rc.d/init.d/ install -m ${MODE} clfs/init.d/localnet ${EXTDIR}/rc.d/init.d/ install -m ${MODE} clfs/init.d/mountfs ${EXTDIR}/rc.d/init.d/ install -m ${MODE} clfs/init.d/mountkernfs ${EXTDIR}/rc.d/init.d/ install -m ${MODE} clfs/init.d/rc ${EXTDIR}/rc.d/init.d/ install -m ${MODE} clfs/init.d/reboot ${EXTDIR}/rc.d/init.d/ install -m ${MODE} clfs/init.d/sendsignals ${EXTDIR}/rc.d/init.d/ install -m ${MODE} clfs/init.d/setclock ${EXTDIR}/rc.d/init.d/ install -m ${MODE} clfs/init.d/swap ${EXTDIR}/rc.d/init.d/ ln -sf ../init.d/sendsignals ${EXTDIR}/rc.d/rc0.d/S60sendsignals ln -sf ../init.d/mountfs ${EXTDIR}/rc.d/rc0.d/S70mountfs ln -sf ../init.d/swap ${EXTDIR}/rc.d/rc0.d/S80swap ln -sf ../init.d/halt ${EXTDIR}/rc.d/rc0.d/S99halt ln -sf ../init.d/sendsignals ${EXTDIR}/rc.d/rc6.d/S60sendsignals ln -sf ../init.d/mountfs ${EXTDIR}/rc.d/rc6.d/S70mountfs ln -sf ../init.d/swap ${EXTDIR}/rc.d/rc6.d/S80swap ln -sf ../init.d/reboot ${EXTDIR}/rc.d/rc6.d/S99reboot ln -sf ../init.d/mountkernfs ${EXTDIR}/rc.d/rcsysinit.d/S00mountkernfs ln -sf ../init.d/udev ${EXTDIR}/rc.d/rcsysinit.d/S10udev ln -sf ../init.d/checkfs ${EXTDIR}/rc.d/rcsysinit.d/S20checkfs ln -sf ../init.d/mountfs ${EXTDIR}/rc.d/rcsysinit.d/S30mountfs ln -sf ../init.d/swap ${EXTDIR}/rc.d/rcsysinit.d/S40swap ln -sf ../init.d/cleanfs ${EXTDIR}/rc.d/rcsysinit.d/S50cleanfs ln -sf ../init.d/setclock ${EXTDIR}/rc.d/rcsysinit.d/S60setclock if [ ! -f ${EXTDIR}/sysconfig/rc ]; then install -m ${CONFMODE} clfs/sysconfig/rc ${EXTDIR}/sysconfig/; fi if [ ! -f ${EXTDIR}/sysconfig/createfiles ]; then install -m ${CONFMODE} clfs/sysconfig/createfiles ${EXTDIR}/sysconfig/; fi @$(MAKE) mknod_devices install-raq2: install -m ${MODE} clfs/init.d/paneld ${EXTDIR}/rc.d/init.d/ ln -sf ../init.d/paneld ${EXTDIR}/rc.d/rc0.d/K01paneld ln -sf ../init.d/paneld ${EXTDIR}/rc.d/rc1.d/S99paneld ln -sf ../init.d/paneld ${EXTDIR}/rc.d/rc2.d/S99paneld ln -sf ../init.d/paneld ${EXTDIR}/rc.d/rc3.d/S99paneld ln -sf ../init.d/paneld ${EXTDIR}/rc.d/rc4.d/S99paneld ln -sf ../init.d/paneld ${EXTDIR}/rc.d/rc5.d/S99paneld ln -sf ../init.d/paneld ${EXTDIR}/rc.d/rc6.d/K01paneld if [ ! -f ${EXTDIR}/sysconfig/lcd ]; then install -m ${CONFMODE} clfs/sysconfig/lcd-raq2 ${EXTDIR}/sysconfig/lcd; fi install-raq3: install -m ${MODE} clfs/init.d/setlcd ${EXTDIR}/rc.d/init.d/ ln -sf ../init.d/setlcd ${EXTDIR}/rc.d/rc0.d/K01setlcd ln -sf ../init.d/setlcd ${EXTDIR}/rc.d/rc1.d/S99setlcd ln -sf ../init.d/setlcd ${EXTDIR}/rc.d/rc2.d/S99setlcd ln -sf ../init.d/setlcd ${EXTDIR}/rc.d/rc3.d/S99setlcd ln -sf ../init.d/setlcd ${EXTDIR}/rc.d/rc4.d/S99setlcd ln -sf ../init.d/setlcd ${EXTDIR}/rc.d/rc5.d/S99setlcd ln -sf ../init.d/setlcd ${EXTDIR}/rc.d/rc6.d/K01setlcd if [ ! -f ${EXTDIR}/sysconfig/lcd ]; then install -m ${CONFMODE} clfs/sysconfig/lcd-raq3 ${EXTDIR}/sysconfig/lcd; fi install-lcd: if [ ! -f ${EXTDIR}/sysconfig/lcd ]; then install -m ${CONFMODE} clfs/sysconfig/lcd ${EXTDIR}/sysconfig/lcd; fi .PHONY: all create-dirs create-service-dir install install-consolelog \ install-service-mtu minimal install-lcd install-raq2 install-raq3